Image6.gif (2801 bytes)

Environmental Technologies Design Option Tool (ETDOT) is a compilation of self-contained simulation software for use in assessing and implementing effective treatment strategies for gaseous, aqueous, organic, and solid waste by-product streams. ETDOT provides simulation software necessary in determining whether prevention or treatment is preferred during the design phase.

ETDOT may be used to evaluate source reduction versus end-of-pipe treatment, integrate treatment into the manufacturing process, evaluate waste segregation versus central treatment, and select and size the most effective environmental technologies. ETDOT is designed for the Microsoft Windowstm.gif (70 bytes) environment with a graphical user interface (GUI) to maximize user-friendliness.

ETDOT Applications:
  • Pollution Prevention
  • Waste Reduction
  • Remediation
  • Water Treatment

Image6.gif (2801 bytes)

Adsorption Design Software (AdDesignS) Features:
  • Adsorption Models developed over the last 22 years at Michigan Technological University
  • Extensive Adsorbent Databases
  • Commercial Adsorber Databases
  • Adsorption Equilibrium Isotherm Parameter Database
  • Equilibrium and Kinetic Parameter Estimation Techniques
(View AdDesignS Slide Show Powerpoint or PDF)
(pdficon.gif (153 bytes)View Brochure PDF - 210KB)
(Download ZIP'ed Word97 Manual - 883KB)

Image6.gif (2801 bytes)

Aeration System Analysis Program (ASAP) Features:
  • Practical and Easy to Use Air Stripping Models for VOC Removal
  • Extensive Vendor Tower Packing Database
  • Design and Rating Mode Options
  • Henry's Law Database and Parameter Estimation Methods
(pdficon.gif (153 bytes)View Brochure PDF - 391KB)
(Download ZIP'ed Word97 Manual - 2,700KB)

Image6.gif (2801 bytes)

Software to Estimate Physical Properties (StEPP) Features:
  • Database of over 600 organic contaminants included on EPA's Title III Consolidated Chemical List
  • Extensive parameter estimation methods to supplement the database
  • Dependence on temperature for those properties that vary strongly with temperature
  • Database includes data from the American Institute of Chemical Engineers/Design Institute for Physical Property Data - AIChE/DIPPR®
(View StEPP Slide Show Powerpoint or PDF)
(pdficon.gif (153 bytes)View Brochure PDF - 114KB)
(Download ZIP'ed Word97 Manual - 333KB)

Image6.gif (2801 bytes)

Advanced Oxidation Process Simulation Software (AdOx) Features:
  • Comprehensive, mechanistic advanced oxidation model for organic contaminants removal
  • Considers most important elementary reactions involved in the H2O2/UV process, the influence of hydroxyl radical scavenging and the attenuation of UV light due to background compounds in the water matrix
  • Modeling of multiple target compounds destruction
  • Variable operation mode options:  provides steady state solution for flow reactors and fully dynamic solution for both batch and flowing systems
  • Predicts the change in pH
  • Photolysis and radical reaction rate constants and photochemical parameters database and estimation methods
  • Also contains dye study model that can analyze pulse dye study data and determine the appropriate number of tanks in series required to describe the mixing conditions in the reactor.  This in turn can be used to select the appropriate number of tanks for designing the photochemical reactor.
(View AdOx Slide Show Powerpoint or PDF)
(pdficon.gif (153 bytes)View Brochure PDF - 184KB)
(Download ZIP'ed Word97 Manual - 1,279KB

Image6.gif (2801 bytes)

Biofilter Design Software (Biofilter) Features:
  • A mathematical model that simulates the processes occurring in a biofilter (or biotrickling filter) that is used to treat odorous air emissions or VOCs
  • Considers advective flow in gas- and liquid-phases
  • Incorporates mass transfer at the gas-liquid and liquid-biofilm interfaces, as well as internal diffusion in the biofilm
  • Considers active biomass growth and decay and biological reaction in the biofilm
(View Biofilter Slide Show Powerpoint or PDF)
(Download ZIP'ed Word97 Manual - 1,431KB

Image6.gif (2801 bytes)

Brochures and Price List:
Printed copies of the ETDOT brochures are available for order, as well as a PDF version of the ETDOT price list.
  
Request Printed Copies of ETDOT Brochures and ETDOT Price List - If you fill out this electronic request form with your name, mailing address, and other information, we will ship you printed copies of the ETDOT brochures and the ETDOT price list. (Note that PDF-format versions of these brochures are available on this page for immediate download.)
pdficon.gif (153 bytes)View ETDOT Price List - 51KB - If you view this PDF-format ETDOT price list, you have the option to print it, fill it out, and mail it to us with the purchase cost of the software.

All shipments are usually made within 2-3 business days of receiving your request.

Image6.gif (2801 bytes)

Future ETDOT Software:
Module Name Beta Version Available
Fate of Volatile Organic (FaVOr) compounds in wastewater treatment facilities No
Adsorption for the Recovery of Organics (AdRecover) No
Ion Exchange Design Software (IonExDesignS) No
Multi-phase Multi-component Catalytic Reactor Software (CatReac) No

Image6.gif (2801 bytes)

Minimum System Requirements:
ETDOT is designed for the Microsoft Windowstm.gif (70 bytes) environment with a graphical user interface (GUI) to maximize user-friendliness. Making use of the Microsoft Windows interface, with its built-in file and hardware control features, frees the engineer from concerns over printer drivers and other "machine" issues and allows more attention to the computational algorithms. The GUI for each program consists of a Microsoft Visual Basictm.gif (70 bytes) front-end shell that calls FORTRAN subroutines to perform the calculations.

The minimum ETDOT system requirements are as follows:

  • An English-language version of Microsoft Windows 95, or Microsoft Windows 98, or Microsoft Windows NT 4.0; in the case of Microsoft Windows NT 4.0, Service Pack 3 or more recent is required
  • A Pentium or more recent processor
  • At least 50 MB of hard drive space
  • At least 32 MB of RAM is recommended
  • A graphic VGA or more recent video display
  • A mouse or other pointing device is recommended

Image6.gif (2801 bytes)

Note on Downloadable Brochures and Manuals:

The downloadable brochures are in Adobe Acrobat format. The downloadable manuals are in Microsoft Word 97 format. If you already have an Adobe Acrobat reader, you will be able to read the downloadable brochures immediately. If not, you should download the free Adobe Acrobat viewer using the link below. If you already have Microsoft Word 97 or more recent, you will be able to read the downloadable manuals immediately.

To download a free copy of Acrobat Reader for reading the files, click [Get Acrobat Reader]

 

    

Image6.gif (2801 bytes)

    
     

 
For comments or problems with this site contact dwhand@mtu.edu
Copyright © 1999-2005.  Michigan Technological University.  All rights reserved.
Revised: 6/7/2005

Related Pages:

tm.gif (70 bytes)     tm.gif (70 bytes)     

National Center for Clean Industrial and Treatment Technologies (CenCITT)

Michigan Technological University

Michigan Tech - Civil and Environmental Engineering